Skip to main content

The AHRQ National Quality Measures Clearinghouse (NQMC, qualitymeasures.ahrq.gov) Web site will not be available after July 16, 2018 because federal funding
through AHRQ will no longer be available to support the NQMC as of that date. For additional information, read our full announcement.
  • Measure Summary
  • NQMC:010953
  • Dec 2014

Diagnostic flexible bronchoscopy: proportion of patients having a flexible bronchoscopy in the unit per year who completed surveys.

British Thoracic Society (BTS). Quality standards for diagnostic flexible bronchoscopy in adults. London (UK): British Thoracic Society (BTS); 2014 Dec. 37 p.  (British Thoracic Society Reports; no. 5). [28 references]

View the original measure documentation External Web Site Policy

This is the current release of the measure.

Primary Measure Domain

Clinical Quality Measures: Process

Secondary Measure Domain

Clinical Quality Measure: Patient Experience

Description

This measure is used to assess the proportion of patients having a flexible bronchoscopy in the unit per year who completed surveys.

Rationale

This standard will enable the prospective and regular evaluation of the quality of the procedure; consent process and written information in bronchoscopy from the patient perspective.

This standard should help to identify inadequacies in local sedation information/procedure arrangements and facilitate local change to improve standards.

The British Thoracic Society (BTS) guideline for diagnostic flexible bronchoscopy in adults (Du Rand et al., 2013) and the BTS guideline for advanced diagnostic and therapeutic flexible bronchoscopy in adults (Du Rand et al., 2011) are the main references for the quality standards.

Evidence for Rationale

British Thoracic Society (BTS). Quality standards for diagnostic flexible bronchoscopy in adults. London (UK): British Thoracic Society (BTS); 2014 Dec. 37 p.  (British Thoracic Society Reports; no. 5). [28 references]

Du Rand IA, Barber PV, Goldring J, Lewis RA, Mandal S, Munavvar M, Rintoul RC, Shah PL, Singh S, Slade MG, Woolley A, British Thoracic Society Interventional Bronchoscopy Guideline Group. British Thoracic Society guideline for advanced diagnostic and therapeutic flexible bronchoscopy in adults. Thorax. 2011 Nov;66(Suppl 3):iii1-21. [131 references] PubMed External Web Site Policy

Du Rand IA, Blaikley J, Booton R, Chaudhuri N, Gupta V, Khalid S, Mandal S, Martin J, Mills J, Navani N, Rahman NM, Wrightson JM, Munavvar M, British Thoracic Society Bronchoscopy Guideline Group. British Thoracic Society guideline for diagnostic flexible bronchoscopy in adults. Thorax. 2013 Aug;68(Suppl 1):i1-44. [303 references] PubMed External Web Site Policy

Primary Health Components

Flexible bronchoscopy; patient feedback survey

Denominator Description

Number of patients having a flexible bronchoscopy in the unit per year

Numerator Description

Number of completed surveys (see the related "Numerator Inclusions/Exclusions" field)

State of Use

Current routine use

Current Use

Internal quality improvement

Measurement Setting

Ambulatory Procedure/Imaging Center

Hospital Inpatient

Hospital Outpatient

Professionals Involved in Delivery of Health Services

Advanced Practice Nurses

Nurses

Physician Assistants

Physicians

Least Aggregated Level of Services Delivery Addressed

Single Health Care Delivery or Public Health Organizations

Statement of Acceptable Minimum Sample Size

Specified

Target Population Age

Adults

Target Population Gender

Either male or female

National Quality Strategy Aim

Better Care

National Quality Strategy Priority

Health and Well-being of Communities
Person- and Family-centered Care
Prevention and Treatment of Leading Causes of Mortality

IOM Care Need

Staying Healthy

IOM Domain

Effectiveness

Patient-centeredness

Case Finding Period

Yearly

Denominator Sampling Frame

Patients associated with provider

Denominator (Index) Event or Characteristic

Diagnostic Evaluation

Denominator Time Window

Does not apply to this measure

Denominator Inclusions/Exclusions

Inclusions
Number of patients having a flexible bronchoscopy in the unit per year

Exclusions
Unspecified

Exclusions/Exceptions

Does not apply to this measure

Numerator Inclusions/Exclusions

Inclusions
Number of completed surveys

Note:

  • At least once yearly patient feedback should be sought. The feedback should include information on the procedure, the consent process and the written information. A sample tool is available on the British Thoracic Society (BTS) Web site which can be adapted for use locally.
  • This should include at least 20 completed surveys from patients, and where more than one operator conducts bronchoscopy, should be for more than one operator.
  • Patient comfort during procedure should be recorded by the assisting nurse during all procedures in this period while observations are taken.

Exclusions
Unspecified

Numerator Search Strategy

Fixed time period or point in time

Data Source

Administrative clinical data

Type of Health State

Does not apply to this measure

Instruments Used and/or Associated with the Measure

Unspecified

Measure Specifies Disaggregation

Does not apply to this measure

Scoring

Rate/Proportion

Interpretation of Score

Desired value is a higher score

Allowance for Patient or Population Factors

Unspecified

Standard of Comparison

Internal time comparison

Original Title

Quality statement 4b.

Measure Collection Name

Quality Standards for Diagnostic Flexible Bronchoscopy in Adults

Submitter

British Thoracic Society - Medical Specialty Society

Developer

British Thoracic Society - Medical Specialty Society

Funding Source(s)

British Thoracic Society

Composition of the Group that Developed the Measure

A Quality Standards Working Group was convened in September 2013, with the following membership:

  • Dr Ingrid Du Rand, Co-Chair, consultant respiratory physician, Hereford
  • Dr M Munavvar, Co-Chair, consultant respiratory physician, Preston
  • Dr Jonathan Bennett, consultant respiratory physician, Leicester
  • Dr John Blaikley, senior lecturer and honorary consultant respiratory physician, Manchester
  • Dr Richard Booton, consultant respiratory physician, Manchester
  • Dr Nazia Chaudhuri, consultant respiratory physician, Manchester
  • Dr James Finnerty, consultant respiratory physician, Chester
  • Dr Vandana Gupta, specialist registrar in respiratory medicine, Manchester
  • Dr Saifudin Khalid, consultant respiratory physician, Blackburn
  • Dr Swapna Mandal, specialist registrar in respiratory medicine, London
  • Ms Julie Martin, respiratory nurse consultant, Manchester
  • Mrs Anne McCloy, lay representative
  • Ms Janet Mills, respiratory nurse, Preston
  • Dr Neal Navani, consultant respiratory physician, London
  • Dr Najib Rahman, consultant respiratory physician, Oxford
  • Dr John Wrightson, consultant respiratory physician, Oxford

Financial Disclosures/Other Potential Conflicts of Interest

Members of the Quality Standards Group submitted Declaration of Interest forms in line with the British Thoracic Society (BTS) policy and copies of forms are available online via the BTS Web site External Web Site Policy or on request from the BTS Head Office.

Adaptation

This measure was not adapted from another source.

Date of Most Current Version in NQMC

2014 Dec

Measure Maintenance

The Quality Standards document will be reviewed in 2018 or following the publication of a revised guideline, whichever is the sooner.

Date of Next Anticipated Revision

2018

Measure Status

This is the current release of the measure.

Source(s)

British Thoracic Society (BTS). Quality standards for diagnostic flexible bronchoscopy in adults. London (UK): British Thoracic Society (BTS); 2014 Dec. 37 p.  (British Thoracic Society Reports; no. 5). [28 references]

Measure Availability

Source available from the British Thoracic Society (BTS) Web site External Web Site Policy.

For more information, contact BTS at 17 Doughty St, London, WC1N 2PL; Tel: ++ 44 (0) 20 7831 8778; Fax: ++ 44 (0) 20 7831 8766; E-mail: bts@brit-thoracic.org.uk; Web site: www.brit-thoracic.org.uk External Web Site Policy.

NQMC Status

This NQMC summary was completed by ECRI Institute on November 15, 2016. The information was verified by the measure developer on January 4, 2017.

Copyright Statement

This NQMC summary is based on the original measure, which is subject to the measure developer's copyright restrictions.

NQMC Disclaimer

The National Quality Measures Clearinghouse™ (NQMC) does not develop, produce, approve, or endorse the measures represented on this site.

All measures summarized by NQMC and hosted on our site are produced under the auspices of medical specialty societies, relevant professional associations, public and private organizations, other government agencies, health care organizations or plans, individuals, and similar entities.

Measures represented on the NQMC Web site are submitted by measure developers, and are screened solely to determine that they meet the NQMC Inclusion Criteria.

NQMC, AHRQ, and its contractor ECRI Institute make no warranties concerning the content or its reliability and/or validity of the quality measures and related materials represented on this site. Moreover, the views and opinions of developers or authors of measures represented on this site do not necessarily state or reflect those of NQMC, AHRQ, or its contractor, ECRI Institute, and inclusion or hosting of measures in NQMC may not be used for advertising or commercial endorsement purposes.

Readers with questions regarding measure content are directed to contact the measure developer.

About NQMC Measure Summaries

NQMC provides structured summaries containing information about measures and their development.

Measure Summary FAQs

Related Content

NGC GUIDELINE SUMMARIES


Measure Summaries

New This Week

View more and sign up for our Newsletter

Get Adobe Reader